소동물 대사 카트 (Small Animal Metabolic Cart)카테고리 없음 2022. 11. 30. 12:41반응형
Small Animal Metabolic Cart
작은 동물의 대사 시스템은 다음을 기록하고 측정하는 데 적합합니다.
- Respiratory Quotient (RQ)
- RER
- O2 consumed and CO2 expired
소동물 대사 카트 (Small Animal Metabolic Cart) 마우스 챔버 ( Mouse Chamber ) : 1.4 리터 ( Liter )
랫 챔버 ( Rat Chamber ) : 5.2 리터 ( Liter )
Each system includes:
- Recorder and Gas Analyzer
- LabScribe Software with the Metabolic Calculations Module
- Calibration Kit
- 1.4L or 5.2L Animal Chamber
- Nafion and tygon Tubing
측정장비
Fitness Assessment Recorder
Metabolic recorder The IX-Peak is suitable for recording and measuring:
- Basal Metabolic Rate (BMR)
- Resting Metabolic Rate (RMR)
- Respiratory Exchange Ratio (RER)
- Sedentary to light activity VO2 and VCO2
- VO2 Max
General sensors Volume, O2, CO2,Temp, Barometric Pressure, HR iWire 2 iWire ports Temp 10 – 50 deg C HR Polar Heart Rate CO2 Sensor Range 0-10% Sense Method NDIR Error < 0.26% CO2 Warm up 5 minutes O2 Sensor Range 0-50 % Sense Method Paramagnetic Linearity < 0.2% O2 Repeatability < 0.2% O2 Drift < 0.4% in 1st 24 Hours, then <0.2% additional the following week, then < 0.2% additional per each following month. Warm up 1 minute Metabolic recorder 연결 Small Animal Respiratory Exchange Ratio (RER)
Convert the Units on Gas Concentration Channels The voltage outputs of the two sensors in the gas analyzer, carbon dioxide on the top and oxygen on the bottom. Other recording windows have been minimized to show detail.
calibration Changes in CO2 and O2 in a closed chamber, and RER in an endothermic animal
데이터 측정 The recording of the expired CO2 over a period of 28 minutes showing a change in concentration by 1%.
RER Calculation Dialog window Data Analysis
RER channel showing the histogram for the ratio of CO2 to O2 The RER channel showing the histogram for the ratio of CO2 to O2 in the endothermicorganism.
The cursors are in position to measure the mean values of the selected interval. The expired oxygen and carbon dioxide concentration and RER of a small animal as displayed in the Analysis window. The cursors are in position to measure the mean values of the selected interval.
T2-T1 values are also recorded Table for recording Mean CO2, O2 and RER values for the endothermic and ectothermic organisms. T2 - T1 values are also recorded.
동물실험 장비의 자세한 정보가 필요하시다면 아래의 연락처로 문의 부탁드립니다.
항상 최선을 다하겠습니다.
감사합니다.
고투바이오
GoTooBio
info@gotoobio.com
010-9379-0955
Gotoobio 고투바이오 동물실험장비 생체신호측정
올인원 생리학 교육 및 연구 시스템 iWorx Data Acquisitionand Analysis Systems Focus : 사용하기 쉬운 장비와 소프트웨어로 생리학 교육 및 연구에 집중 Record : ECG, EMG, EEG, EOG, EGG, GSR, PPG 등 생체신호 측정 Ana
gotoobio.com
2F, 23-2, Hyosin-ro 16-gil, Dong-gu, Daegu, Republic of Korea
반응형